Celle-ci traite de la conformité des appareils et matériels ATEX ainsi que de la conformité de leur installation dans leur environnement industriel. Aussi, le marquage des équipements est obligatoire et se découpe comme suit :
EX -> d -> II -> C -> T6
- Compliance with CENELEC (Ex) standard
- Equipment protection mode (d = explosion-proof enclosure)
- Classification of gas or dust groups (II = Gas)
- Subdivision of gas groups (C = Hydrogen)
- ATEX temperature class corresponding to maximum material surface temperature (T6 = 450°C)
It’s this last criterion that interests us. What are the specifics of ATEX temperature classes? The ADF Systèmes team explains.
ATEX temperature classes
In ATEX regulations, particular attention is paid to temperatures.
Indeed, the various substances, gases, gas vapors and dusts can self-ignite under the effect of a certain degree of heat.
Minimum ignition temperature is used for dusts, and self-ignition temperature for gases and vapors.
The lower these temperatures, the more dangerous a substance is.
Consequently, electrical devices for ATEX applications are classified according to the maximum surface temperature they generate. This must always be below the auto-ignition point.
Special features of gases and vapors
In the case of gases and vapours, a temperature classification system ranging from T1 to T6* is used:
- T1: 450°C
- T2: 300°C
- T3: 200°C
- T4: 135°C
- T5: 100°C
- T6: 85°C
*Marking according to IEC, CENELEC and NEC505.
In practical terms, this means that a T6-rated material will not exceed 85° surface temperature.
Besoin d’un devis ?
Produits de signalisations sonores et lumineuses, systèmes de mise à la terre, signalisation non ATEX, connections ATEX…

Dust specificities
For dust, the maximum surface temperature is specified directly on the marking: for example, T 129°C means that the equipment will not exceed a surface temperature of 129°C.
In the case of dust clouds, maximum surface temperatures must be less than or equal to ⅔ of the ignition temperature.
- Max temperature (C°) = 2/3 of the ignition temperature of a dust cloud (Tci)
In the case of dust layers, the temperature must be limited according to the presence of a dust layer of less than 5mm.
- Max. temperature = 5mm – 75 k (75 k corresponds to the safety coefficient of 75°C)
Finally, the temperature class or maximum surface temperature of ATEX equipment is only valid for a given ambient operating temperature.
Il incombe donc aux utilisateurs de vérifier que cet équipement est destiné à une température conforme à celle prévue lors du classement. Cette démarche fait partie des prérequis pour assurer la sécurité d’un site industriel avec zones ATEX.
Would you like to find out more about ATEX temperature classes?
ADF Systèmes met un point d’honneur à vous guider dans le choix des produits et solutions les plus adaptées selon vos problématiques de sécurité industrielle et de gestion des risques.