{"id":15768881,"date":"2025-01-21T14:21:52","date_gmt":"2025-01-21T14:21:52","guid":{"rendered":"https:\/\/adf-systemes.fr\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/"},"modified":"2026-02-05T14:08:31","modified_gmt":"2026-02-05T14:08:31","slug":"find-out-about-safety-measures-for-hydrogen-related-atex-zones","status":"publish","type":"post","link":"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/","title":{"rendered":"Find out about safety measures for hydrogen-related ATEX zones"},"content":{"rendered":"\n<p><\/p>\n\n<p>As hydrogen plays a growing role in the energy transition, it&#8217;s important to master the regulations and safety measures applicable to <strong>hydrogen ATEX<\/strong> zones. This article will help you to better understand these requirements and guarantee optimum protection for your industrial installations. <br\/><\/p>\n\n<h2 class=\"wp-block-heading\">Identifying risks and hydrogen ATEX zones<\/h2>\n\n<p>\u00a0<\/p>\n\n<p>Hydrogen is a <strong>flammable gas<\/strong> requiring special precautions. In ATEX hydrogen zones, it is important to understand the unique characteristics of this gas. Its low density makes it more likely to <strong>accumulate high up<\/strong>, creating <strong>dangerous pockets<\/strong>.    <\/p>\n\n<p>Hydrogen is difficult to detect: it is <strong>colorless<\/strong> and<strong> odorless<\/strong>, making it difficult to detect without specialized equipment. Use <strong>reliable detectors<\/strong> to continuously monitor its concentration in the air, and<strong> maintain them regularly<\/strong> to ensure their reliability. <\/p>\n\n<p>To help you define hazardous areas, each <strong>ATEX zone<\/strong> is <strong>categorized<\/strong> according to its <strong>degree of danger<\/strong>, and it is the employer&#8217;s duty to<a href=\"https:\/\/adf-systemes.fr\/en\/how-do-you-prevent-the-risks-associated-with-explosive-atmospheres-or-atex\/\">assess the explosion risks<\/a> on his site and <strong>classify the zones<\/strong>. ATEX zoning must therefore be carried out by a qualified professional to ensure a safe workplace.   <\/p>\n\n<p><\/p>\n\n<h2 class=\"wp-block-heading\">Choosing the right ATEX-certified equipment<\/h2>\n\n<p><\/p>\n\n<p>When working in hydrogen ATEX zones, it&#8217;s imperative to choose <strong>equipment that complies with the relevant standards<\/strong>. This equipment must be certified to guarantee maximum protection against the risk of explosion. Make sure every Apparatus is clearly marked with the appropriate <strong>ATEX certification<\/strong>.  <\/p>\n\n<p>It&#8217;s best to opt for equipment specially designed for <strong>high-risk environments.<\/strong> This includes <strong>sensors<\/strong>, <strong>valves <\/strong>and <strong>control systems<\/strong>. These tools are made to withstand harsh conditions while maintaining safety. You&#8217;ll need to check their condition regularly and carry out preventive <strong>maintenance<\/strong>.  <\/p>\n\n<p><\/p>\n\n<h2 class=\"wp-block-heading\">Ensure adequate ventilation in ATEX zones<\/h2>\n\n<p><\/p>\n\n<p>Hydrogen is extremely flammable, so it is important to prevent any <strong>build-up<\/strong>. <a href=\"https:\/\/www.rosenberg-france.fr\/nos-ventilateurs-pour-lhydrogene\/#:~:text=Comment%20%C3%A9vacuer%20l'hydrog%C3%A8ne%20%3F,LIE)%20pour%20l'hydrog%C3%A8ne.\">Ventilation systems<\/a> must be designed to maintain hydrogen concentrations well below explosive limits.<\/p>\n\n<p>Depending on your installation, opt for <strong>natural<\/strong> or <strong>mechanical<\/strong> <strong>ventilation<\/strong>. Fans must be suitable for use in hydrogen ATEX zones and be <strong>corrosion-resistant<\/strong>. Inspect this equipment regularly to ensure it is working properly. Rigorous <strong>maintenance <\/strong>is essential to avoid breakdowns.   <\/p>\n\n<p>The design of ventilation systems must take into account<strong> air flows<\/strong>, potential<strong> obstacles<\/strong> and hydrogen <strong>release points <\/strong>. You can always call in the experts to ensure compliance with safety standards.   <\/p>\n\n<p><\/p>\n\n<h2 class=\"wp-block-heading\">Staff training in hydrogen safety procedures  <\/h2>\n\n<p><\/p>\n\n<p>In hydrogen-related ATEX zones, every team member needs to understand the <strong>associated risks <\/strong>and the <strong>safety measures<\/strong> to be adopted. Regular <strong>training <\/strong>sessions help maintain a high level of vigilance, and knowledge of procedures can prevent accidents. <\/p>\n\n<p>Setting up <strong>incident simulations<\/strong> is an effective way of reinforcing understanding of emergency situations. During these simulations, you should encourage your staff to <strong>ask questions<\/strong> and <strong>share their experiences<\/strong>, as collaboration and the exchange of information improve collective safety.   <\/p>\n\n<p>Your personnel must be familiar with the equipment specific to hydrogen ATEX zones. To do this, make them aware of the need for regular maintenance to prevent malfunctions. <\/p>\n\n<p>Understanding safety measures for hydrogen in ATEX zones is essential for a safe working environment. By applying these protocols, you can prevent the risk of explosion, protect equipment and ensure the safety of personnel. <\/p>\n","protected":false},"excerpt":{"rendered":"<p>As hydrogen plays a growing role in the energy transition, it&#8217;s important to master the regulations and safety measures applicable to hydrogen ATEX zones. This article will help you to better understand these requirements and guarantee optimum protection for your industrial installations. Identifying risks and hydrogen ATEX zones \u00a0 Hydrogen is a flammable gas requiring [&hellip;]<\/p>\n","protected":false},"author":70,"featured_media":15768882,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"off","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[1],"tags":[],"dipi_cpt_category":[],"class_list":["post-15768881","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-non-categorise"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Find out about safety measures for hydrogen-related ATEX zones - ADF Syst\u00e8mes<\/title>\n<meta name=\"description\" content=\"Learn all about safety measures for hydrogen-related ATEX zones and protect your installations.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Find out about safety measures for hydrogen-related ATEX zones - ADF Syst\u00e8mes\" \/>\n<meta property=\"og:description\" content=\"Learn all about safety measures for hydrogen-related ATEX zones and protect your installations.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/\" \/>\n<meta property=\"og:site_name\" content=\"ADF Syst\u00e8mes\" \/>\n<meta property=\"article:published_time\" content=\"2025-01-21T14:21:52+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-05T14:08:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/adf-systemes.fr\/wp-content\/uploads\/2025\/01\/atex-hydrogene.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"612\" \/>\n\t<meta property=\"og:image:height\" content=\"408\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"coline.mary@neocamino.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"coline.mary@neocamino.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\\\/\"},\"author\":{\"name\":\"coline.mary@neocamino.com\",\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/#\\\/schema\\\/person\\\/022013c28244aa8fd37a6ce715d7fcf9\"},\"headline\":\"Find out about safety measures for hydrogen-related ATEX zones\",\"datePublished\":\"2025-01-21T14:21:52+00:00\",\"dateModified\":\"2026-02-05T14:08:31+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\\\/\"},\"wordCount\":520,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/adf-systemes.fr\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/atex-hydrogene.webp\",\"articleSection\":[\"Non cat\u00e9goris\u00e9\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\\\/\",\"url\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\\\/\",\"name\":\"Find out about safety measures for hydrogen-related ATEX zones - ADF Syst\u00e8mes\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/adf-systemes.fr\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/atex-hydrogene.webp\",\"datePublished\":\"2025-01-21T14:21:52+00:00\",\"dateModified\":\"2026-02-05T14:08:31+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/#\\\/schema\\\/person\\\/022013c28244aa8fd37a6ce715d7fcf9\"},\"description\":\"Learn all about safety measures for hydrogen-related ATEX zones and protect your installations.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\\\/#primaryimage\",\"url\":\"https:\\\/\\\/adf-systemes.fr\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/atex-hydrogene.webp\",\"contentUrl\":\"https:\\\/\\\/adf-systemes.fr\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/atex-hydrogene.webp\",\"width\":612,\"height\":408,\"caption\":\"atex-hydrogen\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Find out about safety measures for hydrogen-related ATEX zones\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/\",\"name\":\"ADF Syst\u00e8mes\",\"description\":\"Le sp\u00e9cialiste des solutions de pr\u00e9vention des risques industriels et ATEX\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/#\\\/schema\\\/person\\\/022013c28244aa8fd37a6ce715d7fcf9\",\"name\":\"coline.mary@neocamino.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c91a9d7c445d9f3af52a1f6f84b0cf4ab839af6da520b86994110ea4672faa06?s=96&d=blank&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c91a9d7c445d9f3af52a1f6f84b0cf4ab839af6da520b86994110ea4672faa06?s=96&d=blank&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c91a9d7c445d9f3af52a1f6f84b0cf4ab839af6da520b86994110ea4672faa06?s=96&d=blank&r=g\",\"caption\":\"coline.mary@neocamino.com\"},\"url\":\"https:\\\/\\\/adf-systemes.fr\\\/en\\\/author\\\/coline-maryneocamino-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Find out about safety measures for hydrogen-related ATEX zones - ADF Syst\u00e8mes","description":"Learn all about safety measures for hydrogen-related ATEX zones and protect your installations.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/","og_locale":"en_US","og_type":"article","og_title":"Find out about safety measures for hydrogen-related ATEX zones - ADF Syst\u00e8mes","og_description":"Learn all about safety measures for hydrogen-related ATEX zones and protect your installations.","og_url":"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/","og_site_name":"ADF Syst\u00e8mes","article_published_time":"2025-01-21T14:21:52+00:00","article_modified_time":"2026-02-05T14:08:31+00:00","og_image":[{"width":612,"height":408,"url":"https:\/\/adf-systemes.fr\/wp-content\/uploads\/2025\/01\/atex-hydrogene.webp","type":"image\/webp"}],"author":"coline.mary@neocamino.com","twitter_card":"summary_large_image","twitter_misc":{"Written by":"coline.mary@neocamino.com","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/#article","isPartOf":{"@id":"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/"},"author":{"name":"coline.mary@neocamino.com","@id":"https:\/\/adf-systemes.fr\/en\/#\/schema\/person\/022013c28244aa8fd37a6ce715d7fcf9"},"headline":"Find out about safety measures for hydrogen-related ATEX zones","datePublished":"2025-01-21T14:21:52+00:00","dateModified":"2026-02-05T14:08:31+00:00","mainEntityOfPage":{"@id":"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/"},"wordCount":520,"commentCount":0,"image":{"@id":"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/#primaryimage"},"thumbnailUrl":"https:\/\/adf-systemes.fr\/wp-content\/uploads\/2025\/01\/atex-hydrogene.webp","articleSection":["Non cat\u00e9goris\u00e9"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/","url":"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/","name":"Find out about safety measures for hydrogen-related ATEX zones - ADF Syst\u00e8mes","isPartOf":{"@id":"https:\/\/adf-systemes.fr\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/#primaryimage"},"image":{"@id":"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/#primaryimage"},"thumbnailUrl":"https:\/\/adf-systemes.fr\/wp-content\/uploads\/2025\/01\/atex-hydrogene.webp","datePublished":"2025-01-21T14:21:52+00:00","dateModified":"2026-02-05T14:08:31+00:00","author":{"@id":"https:\/\/adf-systemes.fr\/en\/#\/schema\/person\/022013c28244aa8fd37a6ce715d7fcf9"},"description":"Learn all about safety measures for hydrogen-related ATEX zones and protect your installations.","breadcrumb":{"@id":"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/#primaryimage","url":"https:\/\/adf-systemes.fr\/wp-content\/uploads\/2025\/01\/atex-hydrogene.webp","contentUrl":"https:\/\/adf-systemes.fr\/wp-content\/uploads\/2025\/01\/atex-hydrogene.webp","width":612,"height":408,"caption":"atex-hydrogen"},{"@type":"BreadcrumbList","@id":"https:\/\/adf-systemes.fr\/en\/find-out-about-safety-measures-for-hydrogen-related-atex-zones\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/adf-systemes.fr\/en\/"},{"@type":"ListItem","position":2,"name":"Find out about safety measures for hydrogen-related ATEX zones"}]},{"@type":"WebSite","@id":"https:\/\/adf-systemes.fr\/en\/#website","url":"https:\/\/adf-systemes.fr\/en\/","name":"ADF Syst\u00e8mes","description":"Le sp\u00e9cialiste des solutions de pr\u00e9vention des risques industriels et ATEX","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/adf-systemes.fr\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/adf-systemes.fr\/en\/#\/schema\/person\/022013c28244aa8fd37a6ce715d7fcf9","name":"coline.mary@neocamino.com","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/c91a9d7c445d9f3af52a1f6f84b0cf4ab839af6da520b86994110ea4672faa06?s=96&d=blank&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c91a9d7c445d9f3af52a1f6f84b0cf4ab839af6da520b86994110ea4672faa06?s=96&d=blank&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c91a9d7c445d9f3af52a1f6f84b0cf4ab839af6da520b86994110ea4672faa06?s=96&d=blank&r=g","caption":"coline.mary@neocamino.com"},"url":"https:\/\/adf-systemes.fr\/en\/author\/coline-maryneocamino-com\/"}]}},"jetpack_featured_media_url":"https:\/\/adf-systemes.fr\/wp-content\/uploads\/2025\/01\/atex-hydrogene.webp","_links":{"self":[{"href":"https:\/\/adf-systemes.fr\/en\/wp-json\/wp\/v2\/posts\/15768881","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/adf-systemes.fr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/adf-systemes.fr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/adf-systemes.fr\/en\/wp-json\/wp\/v2\/users\/70"}],"replies":[{"embeddable":true,"href":"https:\/\/adf-systemes.fr\/en\/wp-json\/wp\/v2\/comments?post=15768881"}],"version-history":[{"count":3,"href":"https:\/\/adf-systemes.fr\/en\/wp-json\/wp\/v2\/posts\/15768881\/revisions"}],"predecessor-version":[{"id":15770563,"href":"https:\/\/adf-systemes.fr\/en\/wp-json\/wp\/v2\/posts\/15768881\/revisions\/15770563"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/adf-systemes.fr\/en\/wp-json\/wp\/v2\/media\/15768882"}],"wp:attachment":[{"href":"https:\/\/adf-systemes.fr\/en\/wp-json\/wp\/v2\/media?parent=15768881"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/adf-systemes.fr\/en\/wp-json\/wp\/v2\/categories?post=15768881"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/adf-systemes.fr\/en\/wp-json\/wp\/v2\/tags?post=15768881"},{"taxonomy":"dipi_cpt_category","embeddable":true,"href":"https:\/\/adf-systemes.fr\/en\/wp-json\/wp\/v2\/dipi_cpt_category?post=15768881"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}